The lifetime of your components are subject to change with the quality of the water supplied. For Installation, Videos go to:www.youtube.com/c/ExpressWaterVideo, READ THIS FIRSTPlease pay attention to the following installation and safety recommendations: Read the installation manual before installing this system.NOTE! NOTE! Make sure it is tight, but do not over-tighten. Does this system filter Fluoride, Lead, Pharmaceuticals, and Arsenic?Yes, as well as Cyanide, Phosphate, Pesticides, Sodium, Cadmium, Sulfates, and many other contaminants up to certain levels. Use the Filter Housing Wrench to open the Filter Housings, then remove and dispose of ONLY the following filter cartridges: Sediment Filter, GAC Filter, Carbon Block Filter, and RO Membrane. 0000404337 00000 n
0000292215 00000 n
Be sure to note which side is the front and which side is the back. Make sure you have shut down the RO System (Step 2 in the Prefilters section). 0000260648 00000 n
Make sure to push the Membrane in firmly, then close the Housing by tightening the cap with your hand. Contact Express Water and we will help you arrange your upgrade.Why are there bubbles in the water?Bubbles in your water is a common issue, but they only affect the appearance of your water and pose no risk. 0000017477 00000 n
Add the Insert into the opening at the same end of the Tubing, then bring this end to the Threaded Faucet Stem. If the RO System is connected to a refrigerator do not drain the system through the refrigerator water dispenser. NOTE! 0000370916 00000 n
Flush the system by opening the RO Faucet handle until the stored water is completely emptied and the flow is reduced to a trickle (about 1-5 minutes). Different drill bits are required for stainless steel, porcelain, granite, etc.You may use an existing hole in your counter or sink or drill a new hole (if using an existing hole begin at step 2). 0000147523 00000 n
Incoming WaterIncoming water pressure must be between 40 PSI and 80 PSI. 0000013647 00000 n
Your Water Storage Tanks capacity depends on your incoming water pressure. DO NOT OVERTIGHTEN! 0000371267 00000 n
You have purchased the finest residential Reverse Osmosis Drinking Water System available for your home. 0000022125 00000 n
Remove old filters and dispose of them. Screw the Compression Nut onto the Threaded Faucet Stem with an adjustable wrench. This includes the following: Replace the O-rings on the filter housings, membrane housing, fittings, and filter cartridges. Replace any connectors and filter housings with proper replacement parts. Sanitize your system as often as needed (how often changes with the profile of your areas incoming water). Always use proper replacement filter cartridges with the correct size and length replacements. Replace the Teflon Tape on all threaded connections and fittings. 0000335022 00000 n
0000360077 00000 n
However, the typical tank reaches 2-2.5 gallons. Take half of the Drain Clamp without the Foam Gasket and insert a nut into the recess on each side. Make sure the O-Rings are in their proper locations. 0000012572 00000 n
0000290344 00000 n
All O-Rings, fittings, filter canisters, and Teflon tape wear out after a certain period of time. Pull out the RO Membrane with a pair of pliers. 0000003606 00000 n
Close the RO Faucet handle and wait for 10 minutes then open the Faucet handle again and wait for it to drain completely. Let the water drip for 5 minutes. AFu6Zk? The Tank Valve only controls water leaving the Water Storage Tank. @rG_JTH)#6*66o 0W\/vXfaM*0, lo"}?#1OikFn-J6zCLvLV?N:pnEKdnXh;7UyL
tjh&a'DFOBT`hU~U:W G'cetz3K5~ ^*`xV%AXKn:,]`np#-hO 0000292360 00000 n
0000261353 00000 n
The RO System does stop filling automatically when tank is filled (2-3 hours). Once connected, make sure to check tubing is secure. 0000294399 00000 n
Put the small bottom end of the Stem Tee into the Male Elbow of the RO Membrane Cap. 0000294065 00000 n
0000007873 00000 n
%PDF-1.4
%
0000025919 00000 n
Home Osmosis Reverse Osmosis System Installation Manual, Reverse OsmosisOverall System Connections, Your drinking water is going to be healthier and taste better from now on, and nothing makes us happier. Refer to the image below to see ideal Drain Saddle locations. However, hard water does reduce the lifespan of your Filters. To Cut TubingMake your cuts against a flat cutting surface with a razor blade, or use a handheld tube cutter. 0000022570 00000 n
0000260185 00000 n
Push and hold the Collet in to release the lock while pulling out on the Tube/Plugs.NOTE! 0000388160 00000 n
This filter produces more PH Positive water with antioxidants and up to 20% more oxygen.Ultraviolet Sterilizer and Upgrade KitAdds a UV light sterilization stage to your JRO System. 0000011008 00000 n
0000004685 00000 n
Keep the Tank Valve in the Closed Position until System Startup. 0000031429 00000 n
0000421674 00000 n
0000024653 00000 n
Is there an indicator?The Sediment, GAC, and Carbon Block Filters should be changed every 6 months. 0000004281 00000 n
Your water pressure, incoming water quality, and water temperature will all affect how quickly your RO System fills the Water Storage Tank.How often do I change Filters? Remove the old filter from the holding clips and discard. After the 5th tank is filled you may drink the water. Make sure you measure the length you will need before cutting. (Be sure to check for new leaks during the first 24 hours after restarting.). Repeat steps 6-8 two more times (about 4-6 hours). You will need a clean cloth, dish soap, filter housing wrench, and appropriate Sediment, GAC, and Carbon Block Filters. 0000001276 00000 n
(|#%\+2iJ{Sqifd&%|z+6y'd$;'.n)xzYMGhQhy;5'OLC>)'FIo 9Qe)sM;J4=Z;lk[T""m7fa/Q0XhS-czFdM@hxnESOM/]vU"mIs"&wvEqx]Y 0000003006 00000 n
Make sure the RO Faucet sits in the center of your new or existing hole. 0000010493 00000 n
0000028781 00000 n
0000031465 00000 n
0000256651 00000 n
To remove the Clippull away until it slides out from betweenthe Collet and Fitting. If this is the only/last filter you are replacing continue to the Restarting the System section. Follow all of your state and local laws and codes regarding plumbing even if they differ from what is stated in this manual. Find the half of the Drain Clamp with a hole in its center. Make sure there is equal space on both sides between the Drain Clamp halves.). 0000262200 00000 n
0000009073 00000 n
If this is the only/last filter you are replacing continue to the Restarting the System section. Pull out on the Tube to make sure the lock has activated and the Tubing is secure.NOTE! Insert the small rubber washer, then the base plate, then the large rubber washer (see image on next page) onto the Threaded Faucet Stem at the base of the RO Faucet. The Foam Gasket will be between the drain clamp and the drilled hole. 0000068372 00000 n
The RO Faucet may be installed on any flat surface. Weve marked where the colored tubes will go with matching colored plugs in each fitting.We know life isnt always so simple though. Under the sink install Plastic Washer, Lock Washer, and Hex Nut (see image on next page) onto the Threaded Faucet Stem. 0000016616 00000 n
NOTE!Reference image to place each of the prefilters in the correct order: the orange Sediment Filter will be on the far right (under the label TO FEED). the blue Carbon Block Filter will be on the opposite side, the far left. the green GAC Filter will be in the center, between the other two. Use a proper 1/2 drill bit (depending on your sink/counter material) to make a hole for your RO Faucet. When installing be careful not to touch the filter portion with your hands.Remove the plastic wrap from the 3 Filter Housings and stand them upright. Next, open the cold water handle on your sink to release any pressure by expelling any existing water. }8A[L`@Z1[cKID 3M, 5qaIG1|.nz_)J[RF9Ha:;tvkf>7g=*~FFX?GXWaaS Q%'Mjb19r^H*=M+ISdOh>#T]QHlBR)F9U3/{`I/Of+m ~Ki/vNR6EO/b]}cw}1kqbzp6_'ZoE)[1Xy!zN,o(. 0000022686 00000 n
Put the end of the Pressure Gauge into one of the top arms of the Stem Tee. 0000387980 00000 n
After unwrapping, place the new filters inside their correct housings. endstream
endobj
674 0 obj
<. 0000404547 00000 n
Then remove the backing from the Foam Gasket (the foam circle at the center of the Gasket is disposable). Next, insert the new filter into the holding clips and connect the Stem Elbow and Stem Tee to the new Inline Post Carbon Filter. The Clip must be removed before theTubing can be removed. trailer
<]/Prev 1058531>>
startxref
0
%%EOF
322 0 obj
<>stream
Note the orientation of the old filter, install the new filter in the same orientation. RO Storage TankWater Storage TankTank StandNOTE! (Occasionally check for leaks during this time), Let the tank fill one final time and sit overnight (8+ hours) before flushing the water. Textile will not work if plastic wrap is not removed.Please do not re-use Leak Stop pads once activated. 673 0 obj
<>
endobj
0000004143 00000 n
Push hard enough on the tubing to make sure the Quick Connect has locked before moving on. Make sure you have shut down the RO System (Step 2 in the above section). 0000294669 00000 n
0000005819 00000 n
. If your water is microbiologically unsafe or of unknown quality do not use this system without adequate disinfection before or after the system. If your drain line is constantly flowing this is a sign that your incoming water pressure is too low.Can I install this system in the basement? 90 0 obj <>
endobj
xref
90 111
0000000016 00000 n
If you reach 6 months or 1 year without noticing a change in taste you should still change your filter at this point as they are no longer viable.Can I add additional filters to my current system?Yes, each system is fully upgradeable. 0000023449 00000 n
0000022009 00000 n
You may have other rights depending on your state. Trapped air happens frequently when you change a filter, when there is a leak in your system or plumbing, or even when there is construction in your area. 0000388045 00000 n
NOTE! Use only authentic Express Water filters. The Tubing will go 5/8ths of an inch into the Collet before the lock is activated. The tubing in your RO System uses a Quick Connect locking mechanism to lock the Color Coded Tubing in place. Failure to do so will activate the textile and shut the incoming water. 0000026487 00000 n
The system will release water when it is disassembled.). Screw until tightened and the arm of the Elbow is facing upwards at an 11 OClock angle (use the above image for reference). 0000363686 00000 n
Open the Water Storage Tank box and unscrew the Tank Stand from the threaded stem at the top of the Tank. Push hard enough on the tubing to make sure the Quick Connect has locked before moving on. 0000004942 00000 n
274 0 obj
<>
endobj
xref
274 49
0000000016 00000 n
For purchasing information for replacement filters, please visit our website at www.ExpressWater.com. Why is the drain line constantly flowing? Once you have found where your Drain Saddle will go on the Drain Pipe make a mark for the opening there with a marker or pencil. However, some water takes longer to process. The Drain Saddle is designed to fit around a standard 1.5 inch OD (outer diameter) drain pipe. hbbd```b``+d%d"U`D&&7e!`",@d3d6'H_ d?Cw I
0000010999 00000 n
0000261811 00000 n
If your water pressure is above 80 PSI you will need a pressure regulator for your system. Screw the other Male Elbow Fitting (with red plug) into the leftmost Filter Housing (Carbon Block) marked OUT. 0000010021 00000 n
0000017431 00000 n
0000261038 00000 n
0000003261 00000 n
As shown below, the Feed Water Adapter Valve can be used for 3/8 or 1/2 feed line plumbing. Connection Type B Add the Faucet Adapter to one end of the Blue Tubing. Both will go about 5/8ths inch into the tee to secure. Close any incoming water (Feed Water Adapter Valve). 0000007265 00000 n
0000003435 00000 n
Do not add bleach directly to the filter housing. 694 0 obj
<>/Filter/FlateDecode/ID[<201C1C1F3A22AA418CC2C5A50FA642FB>]/Index[673 33]/Info 672 0 R/Length 104/Prev 467027/Root 674 0 R/Size 706/Type/XRef/W[1 3 1]>>stream
xlOQ7S You may need to carefully tilt the system various directions then set it back in place to help release trapped air.Does this produce aquarium-safe water?While the water is perfectly safe for human consumption, we suggest installing our Deionization Filter Upgrade to create water for aquatic life.Why do I need to flush the system?New filters (or filters that have experienced extended disuse) can develop carbon residue. Porcelain SinkA proper porcelain 1/2 drill bit is strongly recommended to prevent chipping if you are drilling on a porcelain sink. The the flushing process is needed for your filters to begin working.NOTE! 0000021954 00000 n
Install the new RO Membrane in the Housing in the correct direction you noted earlier. Place the Water Storage Tank near the RO System in the desired location. 0000018339 00000 n
0000371031 00000 n
0000294330 00000 n
Open the RO Membrane Housing by unscrewing the cap. HV{kGJ!KR4BQspcIiH? If your system does include a Gauge we will install it now. 0000003321 00000 n
0000404367 00000 n
Finish tightening each housing using the filter wrench. Then open the RO Faucet handle to release pressure, close the handle when the flow of water stops. Lower water pressure means the tank will hold less water. 0000290417 00000 n
0000294695 00000 n
0000317531 00000 n
37(a`~)xVhb-N3t&tQ#lF{ -'6X
,0TDE Y P#g]@ZEN``tdE#jfG)"S\cpwcTK H0j.Q` 3_0
0000170711 00000 n
Make sure each Housing has two O-Rings firmly in place at the top of the Housing and in the Housings lower groove. Make sure the Base Plate is big enough to cover the hole you use. Wash the Prefilter Housings with dish soap then proceed to rinse until all soap is removed. A to B Connect the RED Tubing to the Feed Water Adapter Valve (point A), then to the hole marked as IN on the Leak Stop Valve (point B).C to D Connect the WHITE Tubing to the hole marked as OUT on the Leak Stop Valve (point C), then to the Sediment Filter Housings Male Elbow Fitting (point D).E to F The RED Tubing is already connected to the Automatic Shut-Off Valve (point E), connect the loose end to the Carbon Block Filter Housings Male Elbow Fitting (point F).G to H Connect the BLACK Tubing to the Flow Restrictor side indicated by the arrow on the Restrictor (point G), then to the Drain Saddle (point H).I to J Connect the YELLOW Tubing to the Inline Post Carbon Filters Stem Run Tee (point I), then to the Water Storage Tanks Tank Valve (point J).K to L Connect the BLUE Tubing to the Stem Elbow at the end of the Inline Post Carbon Filter (point K), then to your RO Faucet connection (point L). Then put the Threaded Faucet Stem through the newly drilled or pre-existing hole. The Tank can stand up straight or lie on its side. 0000371390 00000 n
0000260575 00000 n
0000371463 00000 n
0000006762 00000 n
Using HOT WATER will severely damage your RO System. 0000022761 00000 n
RO UnitTop ComponentsInline Post Carbon Filter FLTIN01PKQRO Membrane Filter FLTMEME50 / FLTMEME100Bottom ComponentsFilter Housings PRTHSF10DB14Sediment Filter FLTSED0501GAC Filter FLTGAC0501Carbon Block Filter FLTCAR0501C. Please refer to System Startup section for detailed instructions, ignore any additional sanitation steps therein. Visit expresswater.com for more information. Collet must be held down while pulling up on the tube to release the tube. 0000070746 00000 n
0000007005 00000 n
Screw a Male Elbow Fitting into the rightmost Filter Housing (Sediment) marked IN. 0000403987 00000 n
Check the Upgrades and Accessories section at expresswater.com for more information.Can I connect this system to a refrigerator or icemaker?Yes, you may need an Express Water Refrigerator Kit to do so. %PDF-1.6
%
705 0 obj
<>stream
0000017468 00000 n
0000002340 00000 n
0000262127 00000 n
If your PSI is too low you can purchase a Booster Pumps to aid your system. The RO Membrane is already on the system. Be careful to drill through one side of the pipe and stabilize your pipes while drilling to avoid damaging them. 0000011618 00000 n
Do not drink water from your new system until you have completed System Startup. 0000291700 00000 n
Let us walk you through these options; call us at 1-800-992-8876 or visit expresswater.comDoes this system soften water?Your RO System will soften water. 0000004830 00000 n
Fully open the Feed Water Adapter Valve, Cold Water Supply, and the Tank Valve. 0000003130 00000 n
Screw until tightened and the arm of the Elbow is facing downward. 0
With proper installation it is possible to utilize your discharge water. This will help activate the tank bladder. We recommend emptying the Water Storage Tank four times (which can take 8-12 hours) to release any extra carbon before the water is safe to drink.How much water can the Water Storage Tank hold?The maximum capacity of the tank is 3.2 gallons.